Pre-qualified reusable thermal packaging for extreme conditions
Reusable systems built for performance. Vacuum insulation and PCM technology provide long hold times even under extreme conditions, with the same coolant configuration throughout the year.
✓ vacuum insulation ✓ phase change material ✓ for heavy-duty applications
different box sizes
year-round coolant configuration (universal packout)
payload space
pre-qualified temperature ranges
Compare sizes & hold times
Select a temperature range to compare payload space, dimensions and pre-qualified hold times.
Hold times under ISTA 7D summer and winter profiles.
Swipe horizontally to view more columns.
| Bezeichnung | Produktraum (Liter) | Innenmaß (mm) (LxBxH) | Außenmaß (mm) (LxBxH) | Laufzeit Summer ISTA 7D | Laufzeit Winter ISTA 7D | |
| Slim Line 5 | 5 | 210 x 210 x 125 | 400 x 390 x 292 | ≥ 107 h * | ≥ 167 h * | |
| Slim Line 7 | 7 | 228 x 228 x 140 | 400 x 390 x 292 | ≥ 80 h * | ≥ 168 h * | |
| Slim Line 10 | 10 | 215 x 215 x 215 | 400 x 390 x 382 | ≥ 128 h * | ≥ 167 h * | |
| Slim Line 12 | 12 | 228 x 228 x 228 | 400 x 390 x 382 | ≥ 95 h * | ≥ 168 h * | |
| Slim Line 15 | 15 | 280 x 228 x 228 | 475 x 390 x 382 | ≥ 120 h * | ≥ 167 h * | |
| Slim Line 20 | 20 | 300 x 300 x 228 | 475 x 465 x 382 | ≥ 118 h * | ≥ 166 h * | |
| Slim Line 27 | 27 | 300 x 300 x 300 | 475 x 465 x 455 | ≥ 136 h * | ≥ 167 h * | |
| Slim Line 36 | 36 | 400 x 300 x 300 | 580 x 465 x 455 | ≥ 152 h * | ≥ 167 h * | |
| Slim Line 48 | 48 | 400 x 400 x 300 | 580 x 570 x 455 | ≥ 152 h * | ≥ 167 h * | |
| Slim Line 64 | 64 | 400 x 400 x 400 | 580 x 570 x 560 | ≥ 142 h * | ≥ 167 h * | |
| * Mindestlaufzeit |
Hold times under ISTA 7D summer and winter profiles.
Swipe horizontally to view more columns.
| Bezeichnung | Produktraum (Liter) | Innenmaß (mm) (LxBxH) | Außenmaß (mm) (LxBxH) | Laufzeit Summer ISTA 7D | Laufzeit Winter ISTA 7D | |
| Slim Line 5 | 5 | 210 x 210 x 125 | 400 x 390 x 292 | ≥ 156 h * | ≥ 166 h * | |
| Slim Line 7 | 7 | 228 x 228 x 140 | 400 x 390 x 292 | ≥ 126 h * | ≥ 117 h * | |
| Slim Line 10 | 10 | 215 x 215 x 215 | 400 x 390 x 382 | ≥ 163 h * | ≥ 186 h * | |
| Slim Line 12 | 12 | 228 x 228 x 228 | 400 x 390 x 382 | ≥ 144 h * | ≥ 151 h * | |
| Slim Line 15 | 15 | 280 x 228 x 228 | 475 x 390 x 382 | ≥ 155 h * | ≥ 170 h * | |
| Slim Line 20 | 20 | 300 x 300 x 228 | 475 x 465 x 382 | ≥ 160 h * | ≥ 166 h * | |
| Slim Line 27 | 27 | 300 x 300 x 300 | 475 x 465 x 455 | ≥ 168 h * | ≥ 186 h * | |
| Slim Line 36 | 36 | 400 x 300 x 300 | 580 x 465 x 455 | ≥ 169 h * | ≥ 183 h * | |
| Slim Line 48 | 48 | 400 x 400 x 300 | 580 x 570 x 455 | ≥ 169 h * | ≥ 186 h * | |
| Slim Line 64 | 64 | 400 x 400 x 400 | 580 x 570 x 560 | ≥ 169 h * | ≥ 186 h * | |
| * Mindestlaufzeit |
Hold times for PCM and dry ice configurations.
Swipe horizontally to view more columns.
| Bezeichnung | Produktraum (Liter) | Innenmaß (mm) (LxBxH) | Außenmaß (mm) (LxBxH) | Laufzeit mit PCM | Laufzeit mit Trockeneis | |
| Slim Line 5 | 5 | 210 x 210 x 125 | 400 x 390 x 292 | ≥ 111 h * | ≥ 168 h * | |
| Slim Line 7 | 7 | 228 x 228 x 140 | 400 x 390 x 292 | ≥ 66 h * | ≥ 113 h * | |
| Slim Line 10 | 10 | 215 x 215 x 215 | 400 x 390 x 382 | ≥ 119 h * | ≥ 139 h * | |
| Slim Line 12 | 12 | 228 x 228 x 228 | 400 x 390 x 382 | ≥ 83 h * | ≥ 122 h * | |
| Slim Line 15 | 15 | 280 x 228 x 228 | 475 x 390 x 382 | ≥ 108 h * | ≥ 168 h * | |
| Slim Line 20 | 20 | 300 x 300 x 228 | 475 x 465 x 382 | ≥ 110 h * | ≥ 130 h * | |
| Slim Line 27 | 27 | 300 x 300 x 300 | 475 x 465 x 455 | ≥ 116 h * | ≥ 161 h * | |
| Slim Line 36 | 36 | 400 x 300 x 300 | 580 x 465 x 455 | ≥ 139 h * | ≥ 138 h * | |
| Slim Line 48 | 48 | 400 x 400 x 300 | 580 x 570 x 455 | ≥ 161 h * | ≥ 161 h * | |
| Slim Line 64 | 64 | 400 x 400 x 400 | 580 x 570 x 560 | ≥ 127 h * | ≥ 110 h * | |
| * Mindestlaufzeit |
Dry ice configuration: empty box without coolant elements. Dry ice is not included.
Compact design. Built for long journeys.
VIP & PCM technology
Vacuum insulation with thin walls and suitable PCM coolant elements help maintain the required temperature.
Four temperature configurations
Cold, CRT, Frozen with PCM or dry ice: choose the configuration that suits your shipment.
A consistent packing process
A universal packout for each PCM temperature range simplifies conditioning and packing throughout the year.
Three components. One coordinated system.
01 · Vacuum insulation
VIP panels provide thermal insulation with a low panel thickness.
02 · Suitable coolants
PCM coolant elements are selected for Cold, CRT or Frozen applications. The dry ice version has its own packout.
03 · Robust outer box
The corrugated plastic outer box protects the system during handling and repeated use.
One box. Four applications.
Choose between Cold (+2 to +8 °C), CRT (+15 to +25 °C), Frozen with PCM and dry ice / Deep Frozen. The appropriate configuration depends on the temperature range required for your shipment.
The dry ice configuration is supplied as an empty box without coolant elements. Dry ice is not included.
Tested under demanding temperature profiles.
Slim Line has been pre-qualified in climate chambers using summer and winter profiles in accordance with ISTA 7D. The tests were carried out with an empty payload space.
The achievable hold time depends on the size, temperature configuration and test conditions. Compare the values listed in the product overview.
One packing process. Summer and winter.
For each PCM temperature range, the same coolant elements and pre-conditioning procedure are used in summer and winter.
This consistent procedure reduces seasonal changes and supports standardised packing processes. The dry ice configuration is packed separately.
Designed for repeated handling.
The robust corrugated plastic outer box and protected VIP panels support repeated use throughout the transport cycle.
The protective layers of the vacuum insulation panels help absorb mechanical stresses during packing and handling.
The right size for your shipment.
Pre-qualification using ISTA 7D summer and winter profiles
Slim Line was tested in climate chambers with simulated external temperatures in accordance with ISTA 7D. The tests were carried out with an empty payload space. The following illustration is based on the documented test of Slim Line 36 in the +2 to +8 °C configuration.
Year-round configuration
For each PCM temperature range, the same coolant elements and pre-conditioning procedure are used for summer and winter profiles. This universal packout avoids seasonal changes to the configuration.
Measurement approach
Sensors are positioned at different points along a diagonal through the payload space to record the temperature distribution and document any differences.
Empty payload
The tests were carried out with an empty payload space. This is a particularly demanding thermal configuration, as there is no additional product mass to help stabilise the temperature.
Plan your next shipment with reusable packaging.
Select the size and temperature configuration for your application. Our team will help you find the right Slim Line solution.