Six product lines

From parcel to pallet

Temperature ranges

+25 °C to < −60 °C

Hold times

24 h to 120 h+

Climatic chamber tested

ISTA & AFNOR

Product lines at a glance

Pre-qualified THERMOCON systems

Classic Line

Cost-effective parcel solution based on EPS shippers

Pre-qualified temperature ranges

Hold time

24–120 h

Payload volume

1.3–70 l

Options

12 sizes

Coolant configuration

Water-based / seasonal

Slim Line

High-performance reusable solution with vacuum insulation

Pre-qualified temperature ranges

Hold time

72–144 h

Payload volume

5–64 l

Options

10 sizes

Coolant configuration

PCM / year-round packout

Medi Line

Robust reusable solution for the last mile

Pre-qualified temperature ranges

Hold time

24–48 h

Payload volume

6–18 l

Options

2 sizes

Coolant configuration

PCM

Paper Line

Paper-based single-use systems designed with recycling in mind

Pre-qualified temperature ranges

Hold time

72–96 h

Payload volume

9–70 l

Options

5 sizes

Coolant configuration

Water-based / seasonal

Premium Box

Premium transport case with vacuum insulation

Pre-qualified temperature ranges

Hold time

72–120 h

Payload volume

12 l

Options

1 size

Coolant configuration

PCM

Pallet Line

High-capacity thermal packaging for pallet transport – modular adjustment using extension frames.

Pre-qualified temperature ranges

Hold time

60–120 h

Payload volume

24–1,210 l

Options

11 sizes

Coolant configuration

Water-based / seasonal

One coolant pack. 30 systems.

Our standard THERMOCON coolant pack fits a wide range of sizes and solutions across product lines.

THERMOCON

CLASSIC LINE

THERMOCON

PALLET LINE

THERMOCON

MEDI LINE

THERMOCON

PAPER LINE

Simplified

Procurement & stockholding

Fewer

Variants to manage

Greater

Flexibility in everyday use

Two coolant options.

THERMOCON standard coolant packs: same size, same performance – compatible with 30 systems.
Reusable hard-shell coolant pack or single-use foam brick.

THERMOCON

HARD-SHELL COOLANT PACK

Reusable

THERMOCON

FOAM BRICK

Single-use

Reusable option

Single-use option

Same performance

One shipper. Four temperature ranges.

In most pre-qualified THERMOCON systems, the same basic shipper can be used for different temperature ranges – simply by changing the coolant pack set.

+2 to +8°C

Use one of the following sets:

-15 to -25°C

+15 to +25°C

Use one of these sets:

-60 °C

ONE BASIC SHIPPER. MAXIMUM FLEXIBILITY.

The basic shippers used in all THERMOCON systems are pre-qualified for multiple temperature ranges. This reduces complexity, stockholding, procurement and handling effort.

Select by transport type

Pre-qualified thermal packaging by transport type

The transport type affects shipper format, packout, handling, temperature profile, hold time margin, freight costs and risk. Selection should therefore take account of the shipping route as well as the temperature range.

Parcel shipping

Pre-qualified systems for parcel shipping need to combine thermal performance, ease of handling and cost-effectiveness. Key factors are a repeatable packout, clearly defined conditioning and a system size suited to the payload, hold time and shipping process.

Classic line

Cost-effective parcel solution based on EPS shippers

Pre-qualified temperature ranges

Hold time

24–120 h

Payload volume

1.3–70 l

Options

12 sizes

Coolant configuration

Water-based / seasonal

Slim Line

High-performance reusable solution with vacuum insulation

Pre-qualified temperature ranges

Hold time

72–144 h

Payload volume

5–64 l

Options

10 sizes

Coolant configuration

PCM / year-round packout

Medi Line

Robust reusable solution for the last mile

Pre-qualified temperature ranges

Hold time

24–48 h

Payload volume

6–18 l

Options

2 sizes

Coolant configuration

PCM / year-round packout

Paper Line

Paper-based single-use systems designed with recycling in mind

Pre-qualified temperature ranges

Hold time

72–96 h

Payload volume

9–70 l

Options

5 sizes

Coolant configuration

Water-based / seasonal

Premium Box

Premium transport case with vacuum insulation

Pre-qualified temperature ranges

Hold time

72–120 h

Payload volume

12 l

Options

1 size

Coolant configuration

PCM / year-round packout

Pallet shipping

Pallet shippers can be a suitable choice for larger shipment volumes, air freight or international pharmaceutical shipping lanes. Key considerations are hold times, payload volume, freight costs and product value.

Pallet Line

High-capacity thermal packaging for pallet transport – modular adjustment using extension frames.

Pre-qualified temperature ranges

Hold time

60–120 h

Payload volume

24–1,210 l

Options

11 sizes

Coolant configuration

Water-based / seasonal

Reusable solutions

Reusable systems suit recurring transport processes that can be controlled. Key considerations are return logistics, cleaning, handling, total cost of ownership (TCO) and whether the transport process is sufficiently predictable.

Slim Line

High-performance reusable solution with vacuum insulation

Pre-qualified temperature ranges

Hold time

72–144 h

Payload volume

5–64 l

Options

10 sizes

Coolant configuration

PCM / year-round packout

Medi Line

Robust reusable solution for the last mile

Pre-qualified temperature ranges

Hold time

24–48 h

Payload volume

6–18 l

Options

2 sizes

Coolant configuration

PCM / year-round packout

Premium Box

Premium transport case with vacuum insulation

Pre-qualified temperature ranges

Hold time

72–120 h

Payload volume

12 l

Options

1 size

Coolant configuration

PCM / year-round packout

Das passende vorqualifizierte System für Ihre Anwendung

Wählen Sie zunächst den gewünschten Temperaturbereich. Anschließend grenzen Sie Produktlinie, Kühlmittel und Nutzungskonzept ein.

Temperaturbereich wählen

HINWEIS: Der Temperaturbereich beschreibt die Zieltemperatur des Versandguts – nicht den Schmelzpunkt oder die Phasenwechseltemperatur des Kühlelements. Die Eignung ergibt sich aus Verpackungssystem, Packout und Konditionierung.

Produktlinie, Kühlmittel & Nutzung eingrenzen

Laufzeit-Kategorie

Weitere Filter (optional)

Kühlmittel-Typ

Nutzungskonzept

Transportart

0 passende Produkte

Passende Systeme

Angezeigte Artikel sind nach {pill} gefiltert und gehören zur Produktlinie {card}.

Mehrfachauswahl möglich: Haken Sie alle Produkte an, die für Sie infrage kommen, und fragen Sie sie mit einer einzigen Anfrage gemeinsam an.

Passende Systeme — 183 Varianten
Auswahl Aktion
Cold (+2 bis +8°C) THERMOCON CLASSIC 1.3 CLASSIC 1.3 EPS Paketversand Seasonal summer Wasser 36 h 24 - 48 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 1.3 CLASSIC 1.3 EPS Paketversand Seasonal winter Wasser 36 h+ 24 - 48 h
Ambient / CRT (+15 bis +25°C) THERMOCON CLASSIC 1.3 CLASSIC 1.3 EPS Paketversand Seasonal summer Wasser 42 h+ 24 - 48 h
Ambient / CRT (+15 bis +25°C) THERMOCON CLASSIC 1.3 CLASSIC 1.3 EPS Paketversand Seasonal winter Wasser 27 h 24 - 48 h
Frozen PCM (-25 bis -15°C) THERMOCON CLASSIC 1.3 CLASSIC 1.3 EPS Paketversand Universal PCM 20 h 24 - 48 h
Frozen DI (< -15°C) THERMOCON CLASSIC 1.3 CLASSIC 1.3 EPS Paketversand Universal Trockeneis 65 h 48 - 72 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 2.2 CLASSIC 2.2 EPS Paketversand Seasonal summer Wasser 24 h 24 - 48 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 2.2 CLASSIC 2.2 EPS Paketversand Seasonal winter Wasser 48 h 24 - 48 h
Ambient / CRT (+15 bis +25°C) THERMOCON CLASSIC 2.2 CLASSIC 2.2 EPS Paketversand Seasonal summer Wasser 25 h 24 - 48 h
Frozen DI (< -15°C) THERMOCON CLASSIC 2.2 CLASSIC 2.2 EPS Paketversand Universal Trockeneis 46 h 24 - 48 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 4.8 CLASSIC 4.8 EPS Paketversand Seasonal summer Wasser 48 h 24 - 48 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 4.8 CLASSIC 4.8 EPS Paketversand Seasonal winter Wasser/PCM 96 h 96 - 120 h
Frozen DI (< -15°C) THERMOCON CLASSIC 4.8 CLASSIC 4.8 EPS Paketversand Universal Trockeneis 72 h 72 - 96 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 5.0 CLASSIC 5 EPS Paketversand Seasonal summer Wasser 30 h 24 - 48 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 5.0 CLASSIC 5 EPS Paketversand Seasonal winter Wasser 48 h 24 - 48 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 5.0 CLASSIC 5 EPS Paketversand Seasonal summer Wasser/PCM 46 h 24 - 48 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 5.0 CLASSIC 5 EPS Paketversand Seasonal winter Wasser/PCM 48 h 24 - 48 h
Ambient / CRT (+15 bis +25°C) THERMOCON CLASSIC 5.0 CLASSIC 5 EPS Paketversand Seasonal summer Wasser 26 h 24 - 48 h
Frozen DI (< -15°C) THERMOCON CLASSIC 5.0 CLASSIC 5 EPS Paketversand Universal Trockeneis 40 h 24 - 48 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 6.0 CLASSIC 6 EPS Paketversand Seasonal summer Wasser 52 h 48 - 72 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 6.0 CLASSIC 6 EPS Paketversand Seasonal winter Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON CLASSIC 6.0 CLASSIC 6 EPS Paketversand Seasonal summer Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON CLASSIC 6.0 CLASSIC 6 EPS Paketversand Seasonal winter PCM 75 h 72 - 96 h
Frozen PCM (-25 bis -15°C) THERMOCON CLASSIC 6.0 CLASSIC 6 EPS Paketversand Universal PCM 24 h 24 - 48 h
Frozen DI (< -15°C) THERMOCON CLASSIC 6.0 CLASSIC 6 EPS Paketversand Universal Trockeneis 98 h 96 - 120 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 6.5 CLASSIC 6.5 EPS Paketversand Seasonal summer Wasser 73 h 72 - 96 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 6.5 CLASSIC 6.5 EPS Paketversand Seasonal winter Wasser 120 h+ > 120 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 6.5 CLASSIC 6.5 EPS Paketversand Universal Wasser/PCM 98 h 96 - 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON CLASSIC 6.5 CLASSIC 6.5 EPS Paketversand Seasonal summer Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON CLASSIC 6.5 CLASSIC 6.5 EPS Paketversand Seasonal winter Wasser/PCM 120 h+ > 120 h
Frozen PCM (-25 bis -15°C) THERMOCON CLASSIC 6.5 CLASSIC 6.5 EPS Paketversand Universal PCM 85 h 72 - 96 h
Frozen DI (< -15°C) THERMOCON CLASSIC 6.5 CLASSIC 6.5 EPS Paketversand Universal Trockeneis 120 h+ > 120 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 7.7 CLASSIC 7.7 EPS Paketversand Seasonal summer Wasser 64 h 48 - 72 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 7.7 CLASSIC 7.7 EPS Paketversand Seasonal winter Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON CLASSIC 7.7 CLASSIC 7.7 EPS Paketversand Seasonal summer Wasser 120 h+ > 120 h
Frozen DI (< -15°C) THERMOCON CLASSIC 7.7 CLASSIC 7.7 EPS Paketversand Universal Trockeneis 88 h 72 - 96 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 15 CLASSIC 15 EPS Paketversand Seasonal summer Wasser 79 h 72 - 96 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 15 CLASSIC 15 EPS Paketversand Seasonal winter Wasser 120 h+ > 120 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 15 CLASSIC 15 EPS Paketversand Universal Wasser/PCM 108 h 96 - 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON CLASSIC 15 CLASSIC 15 EPS Paketversand Seasonal summer Wasser 151 h > 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON CLASSIC 15 CLASSIC 15 EPS Paketversand Seasonal winter Wasser/PCM 120 h+ > 120 h
Frozen PCM (-25 bis -15°C) THERMOCON CLASSIC 15 CLASSIC 15 EPS Paketversand Universal PCM 97 h 96 - 120 h
Frozen DI (< -15°C) THERMOCON CLASSIC 15 CLASSIC 15 EPS Paketversand Universal Trockeneis 120 h+ > 120 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 15.5 CLASSIC 15.5 EPS Paketversand Seasonal summer Wasser 84 h 72 - 96 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 15.5 CLASSIC 15.5 EPS Paketversand Seasonal winter Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON CLASSIC 15.5 CLASSIC 15.5 EPS Paketversand Seasonal summer Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON CLASSIC 15.5 CLASSIC 15.5 EPS Paketversand Seasonal winter PCM 110 h 96 - 120 h
Frozen PCM (-25 bis -15°C) THERMOCON CLASSIC 15.5 CLASSIC 15.5 EPS Paketversand Universal PCM 45 h 24 - 48 h
Frozen DI (< -15°C) THERMOCON CLASSIC 15.5 CLASSIC 15.5 EPS Paketversand Universal Trockeneis 126 h > 120 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 24 // HALF PALLET SHIPPER 24 CLASSIC 24 EPS Palettenversand Seasonal summer Wasser 87 h 72 - 96 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 24 // HALF PALLET SHIPPER 24 CLASSIC 24 EPS Palettenversand Seasonal winter Wasser 95 h 72 - 96 h
Ambient / CRT (+15 bis +25°C) THERMOCON CLASSIC 24 // HALF PALLET SHIPPER 24 CLASSIC 24 EPS Palettenversand Seasonal summer Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON CLASSIC 24 // HALF PALLET SHIPPER 24 CLASSIC 24 EPS Palettenversand Seasonal winter Wasser/PCM 76 h 72 - 96 h
Frozen PCM (-25 bis -15°C) THERMOCON CLASSIC 24 // HALF PALLET SHIPPER 24 CLASSIC 24 EPS Palettenversand Universal PCM 52 h 48 - 72 h
Frozen DI (< -15°C) THERMOCON CLASSIC 24 // HALF PALLET SHIPPER 24 CLASSIC 24 EPS Palettenversand Universal Trockeneis 120 h+ > 120 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 53 // HALF PALLET SHIPPER 53 CLASSIC 53 EPS Palettenversand Seasonal summer Wasser 120 h+ > 120 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 53 // HALF PALLET SHIPPER 53 CLASSIC 53 EPS Palettenversand Seasonal winter Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON CLASSIC 53 // HALF PALLET SHIPPER 53 CLASSIC 53 EPS Palettenversand Seasonal summer Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON CLASSIC 53 // HALF PALLET SHIPPER 53 CLASSIC 53 EPS Palettenversand Seasonal winter Wasser/PCM 120 h+ > 120 h
Frozen PCM (-25 bis -15°C) THERMOCON CLASSIC 53 // HALF PALLET SHIPPER 53 CLASSIC 53 EPS Palettenversand Universal PCM 61 h 48 - 72 h
Frozen DI (< -15°C) THERMOCON CLASSIC 53 // HALF PALLET SHIPPER 53 CLASSIC 53 EPS Palettenversand Universal Trockeneis 192 h > 120 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 70 // HALF PALLET SHIPPER 70 CLASSIC 70 EPS Palettenversand Seasonal summer Wasser 120 h+ > 120 h
Cold (+2 bis +8°C) THERMOCON CLASSIC 70 // HALF PALLET SHIPPER 70 CLASSIC 70 EPS Palettenversand Seasonal winter Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON CLASSIC 70 // HALF PALLET SHIPPER 70 CLASSIC 70 EPS Palettenversand Seasonal summer Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON CLASSIC 70 // HALF PALLET SHIPPER 70 CLASSIC 70 EPS Palettenversand Seasonal winter Wasser/PCM 64 h 48 - 72 h
Frozen PCM (-25 bis -15°C) THERMOCON CLASSIC 70 // HALF PALLET SHIPPER 70 CLASSIC 70 EPS Palettenversand Universal PCM 60 h 48 - 72 h
Frozen DI (< -15°C) THERMOCON CLASSIC 70 // HALF PALLET SHIPPER 70 CLASSIC 70 EPS Palettenversand Universal Trockeneis 120 h+ > 120 h
Cold (+2 bis +8°C) EURO PALLET SHIPPER 150 PALLET 150 EPS Palettenversand Seasonal summer Wasser 120 h+ > 120 h
Cold (+2 bis +8°C) EURO PALLET SHIPPER 150 PALLET 150 EPS Palettenversand Seasonal winter Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) EURO PALLET SHIPPER 150 PALLET 150 EPS Palettenversand Seasonal summer Wasser 120 h+ > 120 h
Frozen DI (< -15°C) EURO PALLET SHIPPER 150 PALLET 150 EPS Palettenversand Universal Trockeneis 120 h+ > 120 h
Cold (+2 bis +8°C) EURO PALLET SHIPPER 300 PALLET 300 EPS Palettenversand Seasonal summer Wasser 120 h+ > 120 h
Cold (+2 bis +8°C) EURO PALLET SHIPPER 300 PALLET 300 EPS Palettenversand Seasonal winter Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) EURO PALLET SHIPPER 300 PALLET 300 EPS Palettenversand Seasonal summer Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) EURO PALLET SHIPPER 300 PALLET 300 EPS Palettenversand Seasonal winter Wasser/PCM 120 h+ > 120 h
Frozen DI (< -15°C) EURO PALLET SHIPPER 300 PALLET 300 EPS Palettenversand Universal Trockeneis 120 h+ > 120 h
Cold (+2 bis +8°C) EURO PALLET SHIPPER 445 PALLET 445 EPS Palettenversand Seasonal summer Wasser 113 h 96 - 120 h
Cold (+2 bis +8°C) EURO PALLET SHIPPER 445 PALLET 445 EPS Palettenversand Seasonal winter Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) EURO PALLET SHIPPER 445 PALLET 445 EPS Palettenversand Seasonal summer Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) EURO PALLET SHIPPER 445 PALLET 445 EPS Palettenversand Seasonal winter Wasser/PCM 72 h 48 - 72 h
Frozen DI (< -15°C) EURO PALLET SHIPPER 445 PALLET 445 EPS Palettenversand Universal Trockeneis 120 h+ > 120 h
Cold (+2 bis +8°C) EURO PALLET SHIPPER 590 PALLET 590 EPS Palettenversand Seasonal summer Wasser 111 h 96 - 120 h
Cold (+2 bis +8°C) EURO PALLET SHIPPER 590 PALLET 590 EPS Palettenversand Seasonal winter Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) EURO PALLET SHIPPER 590 PALLET 590 EPS Palettenversand Seasonal summer Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) EURO PALLET SHIPPER 590 PALLET 590 EPS Palettenversand Seasonal winter Wasser/PCM 113 h 96 - 120 h
Frozen DI (< -15°C) EURO PALLET SHIPPER 590 PALLET 590 EPS Palettenversand Universal Trockeneis 108 h 96 - 120 h
Cold (+2 bis +8°C) PALLET TRANSPORTER 610 PALLET 610 EPS Palettenversand Seasonal summer Wasser 112 h 96 - 120 h
Cold (+2 bis +8°C) PALLET TRANSPORTER 610 PALLET 610 EPS Palettenversand Seasonal winter Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) PALLET TRANSPORTER 610 PALLET 610 EPS Palettenversand Seasonal summer Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) PALLET TRANSPORTER 610 PALLET 610 EPS Palettenversand Seasonal winter Wasser/PCM 88 h 72 - 96 h
Frozen PCM (-25 bis -15°C) PALLET TRANSPORTER 610 PALLET 610 EPS Palettenversand Universal PCM 54 h 48 - 72 h
Frozen DI (< -15°C) PALLET TRANSPORTER 610 PALLET 610 EPS Palettenversand Universal Trockeneis 120 h+ > 120 h
Cold (+2 bis +8°C) PALLET TRANSPORTER 910 PALLET 910 EPS Palettenversand Seasonal summer Wasser 102 h 96 - 120 h
Cold (+2 bis +8°C) PALLET TRANSPORTER 910 PALLET 910 EPS Palettenversand Seasonal winter Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) PALLET TRANSPORTER 910 PALLET 910 EPS Palettenversand Seasonal summer Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) PALLET TRANSPORTER 910 PALLET 910 EPS Palettenversand Seasonal winter PCM 120 h+ > 120 h
Frozen PCM (-25 bis -15°C) PALLET TRANSPORTER 910 PALLET 910 EPS Palettenversand Universal PCM 65 h 48 - 72 h
Frozen DI (< -15°C) PALLET TRANSPORTER 910 PALLET 910 EPS Palettenversand Universal Trockeneis 120 h+ > 120 h
Cold (+2 bis +8°C) PALLET TRANSPORTER 1210 PALLET 1210 EPS Palettenversand Seasonal summer Wasser 119 h 96 - 120 h
Cold (+2 bis +8°C) PALLET TRANSPORTER 1210 PALLET 1210 EPS Palettenversand Seasonal winter Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) PALLET TRANSPORTER 1210 PALLET 1210 EPS Palettenversand Seasonal summer Wasser 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) PALLET TRANSPORTER 1210 PALLET 1210 EPS Palettenversand Seasonal winter PCM 110 h 96 - 120 h
Frozen PCM (-25 bis -15°C) PALLET TRANSPORTER 1210 PALLET 1210 EPS Palettenversand Universal PCM 56 h 48 - 72 h
Frozen DI (< -15°C) PALLET TRANSPORTER 1210 PALLET 1210 EPS Palettenversand Universal Trockeneis 120 h+ > 120 h
Cold (+2 bis +8°C) THERMOCON SLIM LINE 5 SLIM 5 VIP Paketversand Universal PCM 107 h+ 96 - 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON SLIM LINE 5 SLIM 5 VIP Paketversand Universal PCM 167 h+ > 120 h
Frozen PCM (-25 bis -15°C) THERMOCON SLIM LINE 5 SLIM 5 VIP Paketversand Universal PCM 156 h+ > 120 h
Frozen DI (< -15°C) THERMOCON SLIM LINE 5 SLIM 5 VIP Paketversand Universal Trockeneis 168 h+ > 120 h
Cold (+2 bis +8°C) THERMOCON SLIM LINE 7 SLIM 7 VIP Paketversand Universal PCM 80 h+ 72 - 96 h
Ambient / CRT (+15 bis +25°C) THERMOCON SLIM LINE 7 SLIM 7 VIP Paketversand Universal PCM 126 h+ > 120 h
Frozen PCM (-25 bis -15°C) THERMOCON SLIM LINE 7 SLIM 7 VIP Paketversand Universal PCM 66 h+ 48 - 72 h
Frozen DI (< -15°C) THERMOCON SLIM LINE 7 SLIM 7 VIP Paketversand Universal Trockeneis 113 h+ 96 - 120 h
Cold (+2 bis +8°C) THERMOCON SLIM LINE 10 SLIM 10 VIP Paketversand Universal PCM 128 h+ > 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON SLIM LINE 10 SLIM 10 VIP Paketversand Universal PCM 163 h+ > 120 h
Frozen PCM (-25 bis -15°C) THERMOCON SLIM LINE 10 SLIM 10 VIP Paketversand Universal PCM 119 h+ 96 - 120 h
Frozen DI (< -15°C) THERMOCON SLIM LINE 10 SLIM 10 VIP Paketversand Universal Trockeneis 139 h+ > 120 h
Cold (+2 bis +8°C) THERMOCON SLIM LINE 12 SLIM 12 VIP Paketversand Universal PCM 98 h+ 96 - 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON SLIM LINE 12 SLIM 12 VIP Paketversand Universal PCM 144 h+ > 120 h
Frozen PCM (-25 bis -15°C) THERMOCON SLIM LINE 12 SLIM 12 VIP Paketversand Universal PCM 83 h+ 72 - 96 h
Frozen DI (< -15°C) THERMOCON SLIM LINE 12 SLIM 12 VIP Paketversand Universal Trockeneis 122 h+ > 120 h
Cold (+2 bis +8°C) THERMOCON SLIM LINE 15 SLIM 15 VIP Paketversand Universal PCM 120 h+ > 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON SLIM LINE 15 SLIM 15 VIP Paketversand Universal PCM 155 h+ > 120 h
Frozen PCM (-25 bis -15°C) THERMOCON SLIM LINE 15 SLIM 15 VIP Paketversand Universal PCM 108 h+ 96 - 120 h
Frozen DI (< -15°C) THERMOCON SLIM LINE 15 SLIM 15 VIP Paketversand Universal Trockeneis 168 h+ > 120 h
Cold (+2 bis +8°C) THERMOCON SLIM LINE 20 SLIM 20 VIP Paketversand Universal PCM 118 h+ 96 - 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON SLIM LINE 20 SLIM 20 VIP Paketversand Universal PCM 160 h+ > 120 h
Frozen PCM (-25 bis -15°C) THERMOCON SLIM LINE 20 SLIM 20 VIP Paketversand Universal PCM 110 h+ 96 - 120 h
Frozen DI (< -15°C) THERMOCON SLIM LINE 20 SLIM 20 VIP Paketversand Universal Trockeneis 130 h+ > 120 h
Cold (+2 bis +8°C) THERMOCON SLIM LINE 27 SLIM 27 VIP Paketversand Universal PCM 136 h+ > 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON SLIM LINE 27 SLIM 27 VIP Paketversand Universal PCM 168 h+ > 120 h
Frozen PCM (-25 bis -15°C) THERMOCON SLIM LINE 27 SLIM 27 VIP Paketversand Universal PCM 116 h+ 96 - 120 h
Frozen DI (< -15°C) THERMOCON SLIM LINE 27 SLIM 27 VIP Paketversand Universal Trockeneis 161 h+ > 120 h
Cold (+2 bis +8°C) THERMOCON SLIM LINE 36 SLIM 36 VIP Paketversand Universal PCM 152 h+ > 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON SLIM LINE 36 SLIM 36 VIP Paketversand Universal PCM 169 h+ > 120 h
Frozen PCM (-25 bis -15°C) THERMOCON SLIM LINE 36 SLIM 36 VIP Paketversand Universal PCM 139 h+ > 120 h
Frozen DI (< -15°C) THERMOCON SLIM LINE 36 SLIM 36 VIP Paketversand Universal Trockeneis 138 h+ > 120 h
Cold (+2 bis +8°C) THERMOCON SLIM LINE 48 SLIM 48 VIP Paketversand Universal PCM 152 h+ > 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON SLIM LINE 48 SLIM 48 VIP Paketversand Universal PCM 169 h+ > 120 h
Frozen PCM (-25 bis -15°C) THERMOCON SLIM LINE 48 SLIM 48 VIP Paketversand Universal PCM 161 h+ > 120 h
Frozen DI (< -15°C) THERMOCON SLIM LINE 48 SLIM 48 VIP Paketversand Universal Trockeneis 161 h+ > 120 h
Cold (+2 bis +8°C) THERMOCON SLIM LINE 64 SLIM 64 VIP Paketversand Universal PCM 142 h+ > 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON SLIM LINE 64 SLIM 64 VIP Paketversand Universal PCM 169 h+ > 120 h
Frozen PCM (-25 bis -15°C) THERMOCON SLIM LINE 64 SLIM 64 VIP Paketversand Universal PCM 127 h+ > 120 h
Frozen DI (< -15°C) THERMOCON SLIM LINE 64 SLIM 64 VIP Paketversand Universal Trockeneis 110 h+ 96 - 120 h
Cold (+2 bis +8°C) THERMOCON MEDI LINE MEDIUM MEDI 6 VIP Paketversand Universal PCM 53 h+ 48 - 72 h
Ambient / CRT (+15 bis +25°C) THERMOCON MEDI LINE MEDIUM MEDI 6 VIP Paketversand Universal PCM 91 h+ 72 - 96 h
Frozen PCM (-25 bis -15°C) THERMOCON MEDI LINE MEDIUM MEDI 6 VIP Paketversand Universal PCM 35 h+ 24 - 48 h
Cold (+2 bis +8°C) THERMOCON MEDI LINE LARGE MEDI 18 VIP Paketversand Universal PCM 68 h+ 48 - 72 h
Ambient / CRT (+15 bis +25°C) THERMOCON MEDI LINE LARGE MEDI 18 VIP Paketversand Universal PCM 91 h+ 72 - 96 h
Frozen PCM (-25 bis -15°C) THERMOCON MEDI LINE LARGE MEDI 18 VIP Paketversand Universal PCM 50 h+ 48 - 72 h
Cold (+2 bis +8°C) THERMOCON PREMIUM 12 PREMIUM 12 VIP Paketversand Universal PCM 102 h+ 96 - 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON PREMIUM 12 PREMIUM 12 VIP Paketversand Universal PCM 72 h+ 48 - 72 h
Frozen PCM (-25 bis -15°C) THERMOCON PREMIUM 12 PREMIUM 12 VIP Paketversand Universal PCM 72 h+ 48 - 72 h
Cold (+2 bis +8°C) THERMOCON PAPER 9 PAPER 9 Papier Paketversand Seasonal summer Wasser 73 h+ 72 - 96 h
Cold (+2 bis +8°C) THERMOCON PAPER 9 PAPER 9 Papier Paketversand Seasonal winter Wasser 99 h+ 96 - 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON PAPER 9 PAPER 9 Papier Paketversand Seasonal summer Wasser 74 h+ 72 - 96 h
Ambient / CRT (+15 bis +25°C) THERMOCON PAPER 9 PAPER 9 Papier Paketversand Seasonal winter PCM 99 h+ 96 - 120 h
Frozen PCM (-25 bis -15°C) THERMOCON PAPER 9 PAPER 9 Papier Paketversand Universal PCM 44 h+ 24 - 48 h
Frozen DI (< -15°C) THERMOCON PAPER 9 PAPER 9 Papier Paketversand Universal Trockeneis 108 h+ 96 - 120 h
Cold (+2 bis +8°C) THERMOCON PAPER 13 PAPER 13 Papier Paketversand Seasonal summer Wasser 82 h+ 72 - 96 h
Cold (+2 bis +8°C) THERMOCON PAPER 13 PAPER 13 Papier Paketversand Seasonal winter Wasser 99 h+ 96 - 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON PAPER 13 PAPER 13 Papier Paketversand Seasonal summer Wasser 81 h+ 72 - 96 h
Ambient / CRT (+15 bis +25°C) THERMOCON PAPER 13 PAPER 13 Papier Paketversand Seasonal winter PCM 80 h+ 72 - 96 h
Frozen PCM (-25 bis -15°C) THERMOCON PAPER 13 PAPER 13 Papier Paketversand Universal PCM 55 h+ 48 - 72 h
Frozen DI (< -15°C) THERMOCON PAPER 13 PAPER 13 Papier Paketversand Universal Trockeneis 116 h+ 96 - 120 h
Cold (+2 bis +8°C) THERMOCON PAPER 30 PAPER 30 Papier Palettenversand Seasonal summer Wasser 75 h+ 72 - 96 h
Cold (+2 bis +8°C) THERMOCON PAPER 30 PAPER 30 Papier Palettenversand Seasonal winter Wasser 99 h+ 96 - 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON PAPER 30 PAPER 30 Papier Palettenversand Seasonal summer Wasser 100 h+ 96 - 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON PAPER 30 PAPER 30 Papier Palettenversand Seasonal winter PCM 99 h+ 96 - 120 h
Frozen PCM (-25 bis -15°C) THERMOCON PAPER 30 PAPER 30 Papier Palettenversand Universal PCM 57 h+ 48 - 72 h
Frozen DI (< -15°C) THERMOCON PAPER 30 PAPER 30 Papier Palettenversand Universal Trockeneis 132 h+ > 120 h
Cold (+2 bis +8°C) THERMOCON PAPER 53 PAPER 53 Papier Palettenversand Seasonal summer Wasser 83 h+ 72 - 96 h
Cold (+2 bis +8°C) THERMOCON PAPER 53 PAPER 53 Papier Palettenversand Seasonal winter Wasser 99 h+ 96 - 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON PAPER 53 PAPER 53 Papier Palettenversand Seasonal summer Wasser 79 h+ 72 - 96 h
Ambient / CRT (+15 bis +25°C) THERMOCON PAPER 53 PAPER 53 Papier Palettenversand Seasonal winter PCM 72 h+ 72 - 96 h
Frozen PCM (-25 bis -15°C) THERMOCON PAPER 53 PAPER 53 Papier Palettenversand Universal PCM 54 h+ 48 - 72 h
Frozen DI (< -15°C) THERMOCON PAPER 53 PAPER 53 Papier Palettenversand Universal Trockeneis 136 h+ > 120 h
Cold (+2 bis +8°C) THERMOCON PAPER 70 PAPER 70 Papier Palettenversand Seasonal summer Wasser 78 h+ 72 - 96 h
Cold (+2 bis +8°C) THERMOCON PAPER 70 PAPER 70 Papier Palettenversand Seasonal winter Wasser 99 h+ 96 - 120 h
Ambient / CRT (+15 bis +25°C) THERMOCON PAPER 70 PAPER 70 Papier Palettenversand Seasonal summer Wasser 76 h+ 72 - 96 h
Ambient / CRT (+15 bis +25°C) THERMOCON PAPER 70 PAPER 70 Papier Palettenversand Seasonal winter PCM 69 h+ 48 - 72 h
Frozen PCM (-25 bis -15°C) THERMOCON PAPER 70 PAPER 70 Papier Palettenversand Universal PCM 46 h+ 24 - 48 h
Frozen DI (< -15°C) THERMOCON PAPER 70 PAPER 70 Papier Palettenversand Universal Trockeneis 120 h+ > 120 h

Understanding pre-qualification

What does “pre-qualified” mean for thermal packaging?

Pre-qualification applies to the tested passive packaging configuration – not to the insulated shipper alone.

The tested system configuration

Insulated shipper

Coolant packs / PCM

Packout

No or minimal payload

Ambient temperature profile

Pre-qualified system

THERMOCON pre-qualifies systems in a worst-case scenario – with no or minimal payload.

Performance data apply to the defined combination of components and test conditions.

Climatic chamber testing under defined conditions

What does the test demonstrate?

The system configuration maintains the specified temperature range for the stated hold time.

Temperature ranges and test profiles

Pre-qualification uses standardised ISTA or AFNOR ambient temperature profiles as well as profiles representative of real-world conditions.

When is reassessment required?

When the product, payload, route, hold time, packing process, coolant conditioning or temperature requirement changes.

Important: no unconditional temperature guarantee

Documented performance applies exclusively to the tested configuration and the
underlying test conditions. Suitability must be assessed for the specific application.

From pre-qualification to qualification

From a pre-qualified system to one qualified for your application

Pre-qualification applies to the tested passive packaging configuration – not to the insulated shipper alone.

01

Pre-qualified system

Tested and documented performance data for a defined configuration and defined conditions.

02

Assessment against the shipping process

The proposed packaging is assessed against the customer’s actual or representative conditions.

03

System qualified for the customer’s application

Thermal performance is demonstrated under conditions representative of the customer’s application.

Pre-qualified system

Product specification

Temperature limits

Actual or representative payload

Packout

Conditioning of coolant packs / PCM packs

Shipping route

Seasonal ambient temperature profiles

Transit time

Handling and transfer points

Safety margin

The result determines the next step

Use the existing system

The pre-qualified system meets the requirements in its existing configuration.

Adapt the packout

The positioning, number or conditioning of coolant packs is adjusted.

Develop a bespoke solution

Bespoke thermal packaging is developed for the specific transport process.

Documented evidence of thermal performance can be incorporated into GDP-compliant transport processes.

Choose a packout

Select by coolant pack configuration

If ambient temperatures along the shipping route are predictable, a seasonal packout can be tailored to summer, winter or transitional conditions. This is often more cost-effective, but requires reliable selection of the correct seasonal configuration. Where ambient temperatures vary widely, on international routes or in hot-to-cold or cold-to-hot shipments, a universal packout is usually more suitable, as a single configuration provides more robust protection under changing ambient conditions.

Seasonal Packout

SUMMER / WINTER CONFIGURATION

Adapted to the seasonal temperature profile

Universal Packout

YEAR-ROUND CONFIGURATION
One configuration for changing ambient conditions

Suitable product lines with seasonal packouts

Classic Line

Cost-effective parcel solution based on EPS shippers

Pre-qualified temperature ranges

Hold time

24–120 h

Payload volume

1.3–70 l

Options

12 sizes

Coolant configuration

Water-based / seasonal

Paper Line

Paper-based single-use systems designed with recycling in mind

Pre-qualified temperature ranges

Hold time

72–96 h

Payload volume

9–70 l

Options

5 sizes

Coolant configuration

Water-based / seasonal

Pallet Line

High-capacity thermal packaging for pallet transport – modular adjustment using extension frames.

Pre-qualified temperature ranges

Hold time

60–120 h

Payload volume

24–1,210 l

Options

11 sizes

Coolant configuration

Water-based / seasonal

Suitable product lines with universal packouts

Slim Line

High-performance reusable solution with vacuum insulation

Pre-qualified temperature ranges

Hold time

72–144 h

Payload volume

5–64 l

Options

10 sizes

Coolant configuration

PCM / year-round packout

Medi Line

Robust reusable solution for the last mile

Pre-qualified temperature ranges

Hold time

24–48 h

Payload volume

6–18 l

Options

2 sizes

Coolant configuration

PCM

Premium Box

Premium transport case with vacuum insulation

Pre-qualified temperature ranges

Hold time

72–120 h

Payload volume

12 l

Options

1 size

Coolant configuration

PCM

Selection guide

Seasonal or universal packout?

The choice depends primarily on the predictability of ambient temperatures, process complexity and product criticality.

Scenario

Suggested approach / recommendation

Ambient temperatures are predictable, seasons are clearly distinguishable and the route is relatively stable.

Reliable temperature profiles or sufficient operational experience are available for the shipping route.

The packout can be tailored to summer, winter or transitional conditions.

A cost-optimised configuration tailored closely to the expected conditions is preferred.

Different seasonal packouts can be selected and handled reliably in the packing process.

Ambient temperatures are difficult to predict, fluctuate widely or change along the route.

Reliable protection is needed for hot-to-cold, cold-to-hot, international or multi-lane shipments.

The correct seasonal configuration cannot be selected reliably in day-to-day operations.

The risk of confusing summer, winter and transitional packouts needs to be minimised.

Standardised packing processes and consistent handling take priority over the lowest possible material costs.

The product is very high-value, urgently needed, difficult to replace, available only in limited quantities or unique.

Product loss would have significant financial, medical or operational consequences.

Particularly strict temperature limits apply and the risk of deviations must be minimised.

A seasonal packout is not inherently less safe when correctly selected and appropriately qualified. A universal packout, however, often reduces the risks associated with incorrect seasonal selection and unexpected ambient temperatures.

Frequently asked questions

What is pre-qualified thermal packaging?

Pre-qualified thermal packaging has been tested as a defined system configuration in climatic chambers – with a specified packout, payload, conditioning, hold time and ambient temperature profile. Under these conditions, testing demonstrated that the temperature in the payload compartment remained within the defined target temperature range for the stated hold time.

Pre-qualified thermal packaging is not automatically suitable for every shipment. It demonstrates the thermal performance of a defined system configuration under specified test conditions. Before use, an assessment is needed to establish whether these conditions adequately represent the specific transport process. Customer-specific temperature data, route, payload or hold time may indicate that changes to the packaging system would be beneficial – for example, to the packout, coolant pack configuration or conditioning.

Yes, it can form part of documented GDP-compliant transport processes. Thermal packaging should be regarded as one element of the overall process. It cannot ensure GDP compliance on its own.

The hold time is the period for which a system remained within the specified temperature range under defined test conditions. Hold times cannot be compared reliably without information on the ambient temperature profile, payload, packout and conditioning.

Typical temperature ranges are +2 to +8 °C, +15 to +25 °C and -15 to -25 °C, alongside dry ice or deep-frozen applications. Bespoke PCM melting points, adapted packouts or customer-specific tests may be appropriate for special requirements.

A climatic chamber test is particularly appropriate when existing test data do not adequately represent the actual transport process, or when product value, product sensitivity, route, temperature requirements, payload, hold time or risk profile call for additional assurance. When qualifying thermal packaging for transport processes subject to GDP requirements, climatic chamber testing is one of the key methods for demonstrating thermal performance under defined or representative conditions. Depending on the application, several rounds of testing and optimisation may be necessary – for example, with different packouts, coolant pack configurations, conditioning procedures, payloads and ambient temperature profiles.

Have a pre-qualified packaging system assessed

Do you already know the required temperature range, hold time, payload or transport type? THERMOCON can help you shortlist a suitable pre-qualified system and assess whether existing data are sufficient for your application or whether an adjustment would be beneficial.

THERMOCON

What would you like to find?

Choose the right product category.

Pre-qualified systems

Matched insulation, cooling elements and packout configurations.

Insulated shippers

Insulated packaging without accessories, suited to your shipping format.

Cooling elements

Gelpacks, foam bricks, rigid cool packs and PCM elements.

Not sure what suits your shipping process?

Get personal advice

THERMOCON

Let’s discuss your shipping needs.

Need product advice or help with a technical question?