Pre-qualified thermal packaging for pharmaceuticals and biotech
Pre-qualification applies to the tested system configuration of insulated shipper, coolant packs and packout – not to the insulated shipper alone.
THERMOCON supplies complete systems tested in climatic chambers for temperature-controlled transport – tested against established ISTA and AFNOR ambient temperature profiles, from single-use parcel shippers to reusable pallet systems.
Six product lines – Classic, Slim, Medi, Paper, Premium and Pallet Line for different transport processes
Single-use or reusable – matched to shipping frequency, return logistics and cost model
Seasonal or universal packout – depending on how predictable ambient temperatures are along the shipping route
+2 to +8 °C, +15 to +25 °C, −15 to −25 °C and < −60 °C – pre-qualified for typical pharmaceutical temperature ranges
Hold times from 24 to over 120 h – demonstrated in climatic chamber tests against ISTA and AFNOR profiles
Payload volumes from 1.3 to 1,210 l – from small parcels to full pallet loads
Our standard THERMOCON coolant pack fits a wide range of sizes and solutions across product lines.
THERMOCON
CLASSIC LINE
THERMOCON
PALLET LINE
THERMOCON
MEDI LINE
THERMOCON
PAPER LINE
Simplified
Procurement & stockholding
Fewer
Variants to manage
Greater
Flexibility in everyday use
Two coolant options.
THERMOCON standard coolant packs: same size, same performance – compatible with 30 systems. Reusable hard-shell coolant pack or single-use foam brick.
THERMOCON
HARD-SHELL COOLANT PACK
Reusable
THERMOCON
FOAM BRICK
Single-use
Reusable option
Single-use option
Same performance
One shipper. Four temperature ranges.
In most pre-qualified THERMOCON systems, the same basic shipper can be used for different temperature ranges – simply by changing the coolant pack set.
+2 to +8°C
Use one of the following sets:
-15 to -25°C
+15 to +25°C
Use one of these sets:
-60 °C
ONE BASIC SHIPPER. MAXIMUM FLEXIBILITY.
The basic shippers used in all THERMOCON systems are pre-qualified for multiple temperature ranges. This reduces complexity, stockholding, procurement and handling effort.
Select by transport type
Pre-qualified thermal packaging by transport type
The transport type affects shipper format, packout, handling, temperature profile, hold time margin, freight costs and risk. Selection should therefore take account of the shipping route as well as the temperature range.
Parcel shipping
Pre-qualified systems for parcel shipping need to combine thermal performance, ease of handling and cost-effectiveness. Key factors are a repeatable packout, clearly defined conditioning and a system size suited to the payload, hold time and shipping process.
Parcel shipping
Single-use
Classic line
Cost-effective parcel solution based on EPS shippers
Pallet shippers can be a suitable choice for larger shipment volumes, air freight or international pharmaceutical shipping lanes. Key considerations are hold times, payload volume, freight costs and product value.
Pallet shipping
Single-use
Pallet Line
High-capacity thermal packaging for pallet transport – modular adjustment using extension frames.
Reusable systems suit recurring transport processes that can be controlled. Key considerations are return logistics, cleaning, handling, total cost of ownership (TCO) and whether the transport process is sufficiently predictable.
Parcel shipping
Reusable
Slim Line
High-performance reusable solution with vacuum insulation
Das passende vorqualifizierte System für Ihre Anwendung
Wählen Sie zunächst den gewünschten Temperaturbereich. Anschließend grenzen Sie Produktlinie, Kühlmittel und Nutzungskonzept ein.
Temperaturbereich wählen
HINWEIS: Der Temperaturbereich beschreibt die Zieltemperatur des Versandguts – nicht den Schmelzpunkt oder die Phasenwechseltemperatur des Kühlelements. Die Eignung ergibt sich aus Verpackungssystem, Packout und Konditionierung.
Produktlinie, Kühlmittel & Nutzung eingrenzen
Paper Line
Papierbasierte Einweg-Paketlösungen
Vollständig recyclingfähige Thermoverpackung auf Papierbasis für temperaturgeführte Sendungen.
Recyclingfähig Entsorgung im Altpapier
Vorqualifiziert Geprüfte Temperaturleitung
Plastikreduziert Nachhaltige Materialwahl
CLASSIC LINE
EPS-basierte Einweg-Paketlösungen
Kostenorientierte Einweglösung aus EPS für temperaturgeführte Sendungen. Effizient, leicht und ideal für pharmazeutische Produkte und Life-Science-Anwendungen.
Vorqualifiziert Geprüfte Temperaturleistung
Recyclinganteil Recycelter Anteil in der EPS-Box
Effizient & leicht Optimale Isolierleistung
MEDI LINE
Robuste Mehrweglösung für die Last Mile
Mehrwegsystem für kurze Transitzeiten von 24 bis 48 Stunden. Ausgelegt auf hohe Umlaufzahlen im Apotheken- und Klinikversand.
24–48 h Laufzeit Für die letzte Meile
Mehrweg Hohe Umlaufzahlen
Vorqualifiziert Geprüfte Temperaturleistung
SLIM LINE
High-Performance Mehrweglösung mit Vakuumisolierung
Vakuumisolierte Mehrweglösung für lange Transitzeiten ab 96 Stunden. Maximale Isolierleistung bei geringem Aufbauvolumen.
72–144 h Laufzeit Interkontinentale Routen
Vakuumisolierung VIP-Paneele
Vorqualifiziert Geprüfte Temperaturleistung
PALLET LINE
Pallet Shipper für Großmengen
Thermoverpackung im Palettenformat für den Versand ganzer Europaletten. Ausgelegt auf Großmengen im Pharma- und Biotech-Transport.
Palettenversand Ganze Europaletten
Lange Laufzeiten Für internationale Routen
Vorqualifiziert Geprüfte Temperaturleistung
PREMIUM BOX
Edler Transportkoffer mit Vakuumisolierung
Hochwertiger Mehrwegkoffer mit Vakuumisolierung für sensible Sendungen mit repräsentativem Anspruch.
72–120 h Laufzeit Lange Transitzeiten
Mehrweg-Koffer Vakuumisoliert
Vorqualifiziert Geprüfte Temperaturleistung
Laufzeit-Kategorie
Weitere Filter (optional)
Kühlmittel-Typ
Nutzungskonzept
Transportart
0passende Produkte
Passende Systeme
Angezeigte Artikel sind nach {pill} gefiltert und gehören zur Produktlinie {card}.
Mehrfachauswahl möglich: Haken Sie alle Produkte an, die für Sie infrage kommen, und fragen Sie sie mit einer einzigen Anfrage gemeinsam an.
Passende Systeme — 183 Varianten
Auswahl
Aktion
Cold (+2 bis +8°C)
THERMOCON CLASSIC 1.3
CLASSIC
1.3
EPS
Paketversand
Seasonal summer
Wasser
36 h
24 - 48 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 1.3
CLASSIC
1.3
EPS
Paketversand
Seasonal winter
Wasser
36 h+
24 - 48 h
Ambient / CRT (+15 bis +25°C)
THERMOCON CLASSIC 1.3
CLASSIC
1.3
EPS
Paketversand
Seasonal summer
Wasser
42 h+
24 - 48 h
Ambient / CRT (+15 bis +25°C)
THERMOCON CLASSIC 1.3
CLASSIC
1.3
EPS
Paketversand
Seasonal winter
Wasser
27 h
24 - 48 h
Frozen PCM (-25 bis -15°C)
THERMOCON CLASSIC 1.3
CLASSIC
1.3
EPS
Paketversand
Universal
PCM
20 h
24 - 48 h
Frozen DI (< -15°C)
THERMOCON CLASSIC 1.3
CLASSIC
1.3
EPS
Paketversand
Universal
Trockeneis
65 h
48 - 72 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 2.2
CLASSIC
2.2
EPS
Paketversand
Seasonal summer
Wasser
24 h
24 - 48 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 2.2
CLASSIC
2.2
EPS
Paketversand
Seasonal winter
Wasser
48 h
24 - 48 h
Ambient / CRT (+15 bis +25°C)
THERMOCON CLASSIC 2.2
CLASSIC
2.2
EPS
Paketversand
Seasonal summer
Wasser
25 h
24 - 48 h
Frozen DI (< -15°C)
THERMOCON CLASSIC 2.2
CLASSIC
2.2
EPS
Paketversand
Universal
Trockeneis
46 h
24 - 48 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 4.8
CLASSIC
4.8
EPS
Paketversand
Seasonal summer
Wasser
48 h
24 - 48 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 4.8
CLASSIC
4.8
EPS
Paketversand
Seasonal winter
Wasser/PCM
96 h
96 - 120 h
Frozen DI (< -15°C)
THERMOCON CLASSIC 4.8
CLASSIC
4.8
EPS
Paketversand
Universal
Trockeneis
72 h
72 - 96 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 5.0
CLASSIC
5
EPS
Paketversand
Seasonal summer
Wasser
30 h
24 - 48 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 5.0
CLASSIC
5
EPS
Paketversand
Seasonal winter
Wasser
48 h
24 - 48 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 5.0
CLASSIC
5
EPS
Paketversand
Seasonal summer
Wasser/PCM
46 h
24 - 48 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 5.0
CLASSIC
5
EPS
Paketversand
Seasonal winter
Wasser/PCM
48 h
24 - 48 h
Ambient / CRT (+15 bis +25°C)
THERMOCON CLASSIC 5.0
CLASSIC
5
EPS
Paketversand
Seasonal summer
Wasser
26 h
24 - 48 h
Frozen DI (< -15°C)
THERMOCON CLASSIC 5.0
CLASSIC
5
EPS
Paketversand
Universal
Trockeneis
40 h
24 - 48 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 6.0
CLASSIC
6
EPS
Paketversand
Seasonal summer
Wasser
52 h
48 - 72 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 6.0
CLASSIC
6
EPS
Paketversand
Seasonal winter
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON CLASSIC 6.0
CLASSIC
6
EPS
Paketversand
Seasonal summer
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON CLASSIC 6.0
CLASSIC
6
EPS
Paketversand
Seasonal winter
PCM
75 h
72 - 96 h
Frozen PCM (-25 bis -15°C)
THERMOCON CLASSIC 6.0
CLASSIC
6
EPS
Paketversand
Universal
PCM
24 h
24 - 48 h
Frozen DI (< -15°C)
THERMOCON CLASSIC 6.0
CLASSIC
6
EPS
Paketversand
Universal
Trockeneis
98 h
96 - 120 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 6.5
CLASSIC
6.5
EPS
Paketversand
Seasonal summer
Wasser
73 h
72 - 96 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 6.5
CLASSIC
6.5
EPS
Paketversand
Seasonal winter
Wasser
120 h+
> 120 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 6.5
CLASSIC
6.5
EPS
Paketversand
Universal
Wasser/PCM
98 h
96 - 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON CLASSIC 6.5
CLASSIC
6.5
EPS
Paketversand
Seasonal summer
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON CLASSIC 6.5
CLASSIC
6.5
EPS
Paketversand
Seasonal winter
Wasser/PCM
120 h+
> 120 h
Frozen PCM (-25 bis -15°C)
THERMOCON CLASSIC 6.5
CLASSIC
6.5
EPS
Paketversand
Universal
PCM
85 h
72 - 96 h
Frozen DI (< -15°C)
THERMOCON CLASSIC 6.5
CLASSIC
6.5
EPS
Paketversand
Universal
Trockeneis
120 h+
> 120 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 7.7
CLASSIC
7.7
EPS
Paketversand
Seasonal summer
Wasser
64 h
48 - 72 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 7.7
CLASSIC
7.7
EPS
Paketversand
Seasonal winter
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON CLASSIC 7.7
CLASSIC
7.7
EPS
Paketversand
Seasonal summer
Wasser
120 h+
> 120 h
Frozen DI (< -15°C)
THERMOCON CLASSIC 7.7
CLASSIC
7.7
EPS
Paketversand
Universal
Trockeneis
88 h
72 - 96 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 15
CLASSIC
15
EPS
Paketversand
Seasonal summer
Wasser
79 h
72 - 96 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 15
CLASSIC
15
EPS
Paketversand
Seasonal winter
Wasser
120 h+
> 120 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 15
CLASSIC
15
EPS
Paketversand
Universal
Wasser/PCM
108 h
96 - 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON CLASSIC 15
CLASSIC
15
EPS
Paketversand
Seasonal summer
Wasser
151 h
> 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON CLASSIC 15
CLASSIC
15
EPS
Paketversand
Seasonal winter
Wasser/PCM
120 h+
> 120 h
Frozen PCM (-25 bis -15°C)
THERMOCON CLASSIC 15
CLASSIC
15
EPS
Paketversand
Universal
PCM
97 h
96 - 120 h
Frozen DI (< -15°C)
THERMOCON CLASSIC 15
CLASSIC
15
EPS
Paketversand
Universal
Trockeneis
120 h+
> 120 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 15.5
CLASSIC
15.5
EPS
Paketversand
Seasonal summer
Wasser
84 h
72 - 96 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 15.5
CLASSIC
15.5
EPS
Paketversand
Seasonal winter
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON CLASSIC 15.5
CLASSIC
15.5
EPS
Paketversand
Seasonal summer
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON CLASSIC 15.5
CLASSIC
15.5
EPS
Paketversand
Seasonal winter
PCM
110 h
96 - 120 h
Frozen PCM (-25 bis -15°C)
THERMOCON CLASSIC 15.5
CLASSIC
15.5
EPS
Paketversand
Universal
PCM
45 h
24 - 48 h
Frozen DI (< -15°C)
THERMOCON CLASSIC 15.5
CLASSIC
15.5
EPS
Paketversand
Universal
Trockeneis
126 h
> 120 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 24 //
HALF PALLET SHIPPER 24
CLASSIC
24
EPS
Palettenversand
Seasonal summer
Wasser
87 h
72 - 96 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 24 //
HALF PALLET SHIPPER 24
CLASSIC
24
EPS
Palettenversand
Seasonal winter
Wasser
95 h
72 - 96 h
Ambient / CRT (+15 bis +25°C)
THERMOCON CLASSIC 24 //
HALF PALLET SHIPPER 24
CLASSIC
24
EPS
Palettenversand
Seasonal summer
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON CLASSIC 24 //
HALF PALLET SHIPPER 24
CLASSIC
24
EPS
Palettenversand
Seasonal winter
Wasser/PCM
76 h
72 - 96 h
Frozen PCM (-25 bis -15°C)
THERMOCON CLASSIC 24 //
HALF PALLET SHIPPER 24
CLASSIC
24
EPS
Palettenversand
Universal
PCM
52 h
48 - 72 h
Frozen DI (< -15°C)
THERMOCON CLASSIC 24 //
HALF PALLET SHIPPER 24
CLASSIC
24
EPS
Palettenversand
Universal
Trockeneis
120 h+
> 120 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 53 //
HALF PALLET SHIPPER 53
CLASSIC
53
EPS
Palettenversand
Seasonal summer
Wasser
120 h+
> 120 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 53 //
HALF PALLET SHIPPER 53
CLASSIC
53
EPS
Palettenversand
Seasonal winter
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON CLASSIC 53 //
HALF PALLET SHIPPER 53
CLASSIC
53
EPS
Palettenversand
Seasonal summer
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON CLASSIC 53 //
HALF PALLET SHIPPER 53
CLASSIC
53
EPS
Palettenversand
Seasonal winter
Wasser/PCM
120 h+
> 120 h
Frozen PCM (-25 bis -15°C)
THERMOCON CLASSIC 53 //
HALF PALLET SHIPPER 53
CLASSIC
53
EPS
Palettenversand
Universal
PCM
61 h
48 - 72 h
Frozen DI (< -15°C)
THERMOCON CLASSIC 53 //
HALF PALLET SHIPPER 53
CLASSIC
53
EPS
Palettenversand
Universal
Trockeneis
192 h
> 120 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 70 //
HALF PALLET SHIPPER 70
CLASSIC
70
EPS
Palettenversand
Seasonal summer
Wasser
120 h+
> 120 h
Cold (+2 bis +8°C)
THERMOCON CLASSIC 70 //
HALF PALLET SHIPPER 70
CLASSIC
70
EPS
Palettenversand
Seasonal winter
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON CLASSIC 70 //
HALF PALLET SHIPPER 70
CLASSIC
70
EPS
Palettenversand
Seasonal summer
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON CLASSIC 70 //
HALF PALLET SHIPPER 70
CLASSIC
70
EPS
Palettenversand
Seasonal winter
Wasser/PCM
64 h
48 - 72 h
Frozen PCM (-25 bis -15°C)
THERMOCON CLASSIC 70 //
HALF PALLET SHIPPER 70
CLASSIC
70
EPS
Palettenversand
Universal
PCM
60 h
48 - 72 h
Frozen DI (< -15°C)
THERMOCON CLASSIC 70 //
HALF PALLET SHIPPER 70
CLASSIC
70
EPS
Palettenversand
Universal
Trockeneis
120 h+
> 120 h
Cold (+2 bis +8°C)
EURO PALLET SHIPPER 150
PALLET
150
EPS
Palettenversand
Seasonal summer
Wasser
120 h+
> 120 h
Cold (+2 bis +8°C)
EURO PALLET SHIPPER 150
PALLET
150
EPS
Palettenversand
Seasonal winter
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
EURO PALLET SHIPPER 150
PALLET
150
EPS
Palettenversand
Seasonal summer
Wasser
120 h+
> 120 h
Frozen DI (< -15°C)
EURO PALLET SHIPPER 150
PALLET
150
EPS
Palettenversand
Universal
Trockeneis
120 h+
> 120 h
Cold (+2 bis +8°C)
EURO PALLET SHIPPER 300
PALLET
300
EPS
Palettenversand
Seasonal summer
Wasser
120 h+
> 120 h
Cold (+2 bis +8°C)
EURO PALLET SHIPPER 300
PALLET
300
EPS
Palettenversand
Seasonal winter
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
EURO PALLET SHIPPER 300
PALLET
300
EPS
Palettenversand
Seasonal summer
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
EURO PALLET SHIPPER 300
PALLET
300
EPS
Palettenversand
Seasonal winter
Wasser/PCM
120 h+
> 120 h
Frozen DI (< -15°C)
EURO PALLET SHIPPER 300
PALLET
300
EPS
Palettenversand
Universal
Trockeneis
120 h+
> 120 h
Cold (+2 bis +8°C)
EURO PALLET SHIPPER 445
PALLET
445
EPS
Palettenversand
Seasonal summer
Wasser
113 h
96 - 120 h
Cold (+2 bis +8°C)
EURO PALLET SHIPPER 445
PALLET
445
EPS
Palettenversand
Seasonal winter
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
EURO PALLET SHIPPER 445
PALLET
445
EPS
Palettenversand
Seasonal summer
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
EURO PALLET SHIPPER 445
PALLET
445
EPS
Palettenversand
Seasonal winter
Wasser/PCM
72 h
48 - 72 h
Frozen DI (< -15°C)
EURO PALLET SHIPPER 445
PALLET
445
EPS
Palettenversand
Universal
Trockeneis
120 h+
> 120 h
Cold (+2 bis +8°C)
EURO PALLET SHIPPER 590
PALLET
590
EPS
Palettenversand
Seasonal summer
Wasser
111 h
96 - 120 h
Cold (+2 bis +8°C)
EURO PALLET SHIPPER 590
PALLET
590
EPS
Palettenversand
Seasonal winter
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
EURO PALLET SHIPPER 590
PALLET
590
EPS
Palettenversand
Seasonal summer
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
EURO PALLET SHIPPER 590
PALLET
590
EPS
Palettenversand
Seasonal winter
Wasser/PCM
113 h
96 - 120 h
Frozen DI (< -15°C)
EURO PALLET SHIPPER 590
PALLET
590
EPS
Palettenversand
Universal
Trockeneis
108 h
96 - 120 h
Cold (+2 bis +8°C)
PALLET TRANSPORTER 610
PALLET
610
EPS
Palettenversand
Seasonal summer
Wasser
112 h
96 - 120 h
Cold (+2 bis +8°C)
PALLET TRANSPORTER 610
PALLET
610
EPS
Palettenversand
Seasonal winter
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
PALLET TRANSPORTER 610
PALLET
610
EPS
Palettenversand
Seasonal summer
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
PALLET TRANSPORTER 610
PALLET
610
EPS
Palettenversand
Seasonal winter
Wasser/PCM
88 h
72 - 96 h
Frozen PCM (-25 bis -15°C)
PALLET TRANSPORTER 610
PALLET
610
EPS
Palettenversand
Universal
PCM
54 h
48 - 72 h
Frozen DI (< -15°C)
PALLET TRANSPORTER 610
PALLET
610
EPS
Palettenversand
Universal
Trockeneis
120 h+
> 120 h
Cold (+2 bis +8°C)
PALLET TRANSPORTER 910
PALLET
910
EPS
Palettenversand
Seasonal summer
Wasser
102 h
96 - 120 h
Cold (+2 bis +8°C)
PALLET TRANSPORTER 910
PALLET
910
EPS
Palettenversand
Seasonal winter
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
PALLET TRANSPORTER 910
PALLET
910
EPS
Palettenversand
Seasonal summer
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
PALLET TRANSPORTER 910
PALLET
910
EPS
Palettenversand
Seasonal winter
PCM
120 h+
> 120 h
Frozen PCM (-25 bis -15°C)
PALLET TRANSPORTER 910
PALLET
910
EPS
Palettenversand
Universal
PCM
65 h
48 - 72 h
Frozen DI (< -15°C)
PALLET TRANSPORTER 910
PALLET
910
EPS
Palettenversand
Universal
Trockeneis
120 h+
> 120 h
Cold (+2 bis +8°C)
PALLET TRANSPORTER 1210
PALLET
1210
EPS
Palettenversand
Seasonal summer
Wasser
119 h
96 - 120 h
Cold (+2 bis +8°C)
PALLET TRANSPORTER 1210
PALLET
1210
EPS
Palettenversand
Seasonal winter
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
PALLET TRANSPORTER 1210
PALLET
1210
EPS
Palettenversand
Seasonal summer
Wasser
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
PALLET TRANSPORTER 1210
PALLET
1210
EPS
Palettenversand
Seasonal winter
PCM
110 h
96 - 120 h
Frozen PCM (-25 bis -15°C)
PALLET TRANSPORTER 1210
PALLET
1210
EPS
Palettenversand
Universal
PCM
56 h
48 - 72 h
Frozen DI (< -15°C)
PALLET TRANSPORTER 1210
PALLET
1210
EPS
Palettenversand
Universal
Trockeneis
120 h+
> 120 h
Cold (+2 bis +8°C)
THERMOCON SLIM LINE 5
SLIM
5
VIP
Paketversand
Universal
PCM
107 h+
96 - 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON SLIM LINE 5
SLIM
5
VIP
Paketversand
Universal
PCM
167 h+
> 120 h
Frozen PCM (-25 bis -15°C)
THERMOCON SLIM LINE 5
SLIM
5
VIP
Paketversand
Universal
PCM
156 h+
> 120 h
Frozen DI (< -15°C)
THERMOCON SLIM LINE 5
SLIM
5
VIP
Paketversand
Universal
Trockeneis
168 h+
> 120 h
Cold (+2 bis +8°C)
THERMOCON SLIM LINE 7
SLIM
7
VIP
Paketversand
Universal
PCM
80 h+
72 - 96 h
Ambient / CRT (+15 bis +25°C)
THERMOCON SLIM LINE 7
SLIM
7
VIP
Paketversand
Universal
PCM
126 h+
> 120 h
Frozen PCM (-25 bis -15°C)
THERMOCON SLIM LINE 7
SLIM
7
VIP
Paketversand
Universal
PCM
66 h+
48 - 72 h
Frozen DI (< -15°C)
THERMOCON SLIM LINE 7
SLIM
7
VIP
Paketversand
Universal
Trockeneis
113 h+
96 - 120 h
Cold (+2 bis +8°C)
THERMOCON SLIM LINE 10
SLIM
10
VIP
Paketversand
Universal
PCM
128 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON SLIM LINE 10
SLIM
10
VIP
Paketversand
Universal
PCM
163 h+
> 120 h
Frozen PCM (-25 bis -15°C)
THERMOCON SLIM LINE 10
SLIM
10
VIP
Paketversand
Universal
PCM
119 h+
96 - 120 h
Frozen DI (< -15°C)
THERMOCON SLIM LINE 10
SLIM
10
VIP
Paketversand
Universal
Trockeneis
139 h+
> 120 h
Cold (+2 bis +8°C)
THERMOCON SLIM LINE 12
SLIM
12
VIP
Paketversand
Universal
PCM
98 h+
96 - 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON SLIM LINE 12
SLIM
12
VIP
Paketversand
Universal
PCM
144 h+
> 120 h
Frozen PCM (-25 bis -15°C)
THERMOCON SLIM LINE 12
SLIM
12
VIP
Paketversand
Universal
PCM
83 h+
72 - 96 h
Frozen DI (< -15°C)
THERMOCON SLIM LINE 12
SLIM
12
VIP
Paketversand
Universal
Trockeneis
122 h+
> 120 h
Cold (+2 bis +8°C)
THERMOCON SLIM LINE 15
SLIM
15
VIP
Paketversand
Universal
PCM
120 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON SLIM LINE 15
SLIM
15
VIP
Paketversand
Universal
PCM
155 h+
> 120 h
Frozen PCM (-25 bis -15°C)
THERMOCON SLIM LINE 15
SLIM
15
VIP
Paketversand
Universal
PCM
108 h+
96 - 120 h
Frozen DI (< -15°C)
THERMOCON SLIM LINE 15
SLIM
15
VIP
Paketversand
Universal
Trockeneis
168 h+
> 120 h
Cold (+2 bis +8°C)
THERMOCON SLIM LINE 20
SLIM
20
VIP
Paketversand
Universal
PCM
118 h+
96 - 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON SLIM LINE 20
SLIM
20
VIP
Paketversand
Universal
PCM
160 h+
> 120 h
Frozen PCM (-25 bis -15°C)
THERMOCON SLIM LINE 20
SLIM
20
VIP
Paketversand
Universal
PCM
110 h+
96 - 120 h
Frozen DI (< -15°C)
THERMOCON SLIM LINE 20
SLIM
20
VIP
Paketversand
Universal
Trockeneis
130 h+
> 120 h
Cold (+2 bis +8°C)
THERMOCON SLIM LINE 27
SLIM
27
VIP
Paketversand
Universal
PCM
136 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON SLIM LINE 27
SLIM
27
VIP
Paketversand
Universal
PCM
168 h+
> 120 h
Frozen PCM (-25 bis -15°C)
THERMOCON SLIM LINE 27
SLIM
27
VIP
Paketversand
Universal
PCM
116 h+
96 - 120 h
Frozen DI (< -15°C)
THERMOCON SLIM LINE 27
SLIM
27
VIP
Paketversand
Universal
Trockeneis
161 h+
> 120 h
Cold (+2 bis +8°C)
THERMOCON SLIM LINE 36
SLIM
36
VIP
Paketversand
Universal
PCM
152 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON SLIM LINE 36
SLIM
36
VIP
Paketversand
Universal
PCM
169 h+
> 120 h
Frozen PCM (-25 bis -15°C)
THERMOCON SLIM LINE 36
SLIM
36
VIP
Paketversand
Universal
PCM
139 h+
> 120 h
Frozen DI (< -15°C)
THERMOCON SLIM LINE 36
SLIM
36
VIP
Paketversand
Universal
Trockeneis
138 h+
> 120 h
Cold (+2 bis +8°C)
THERMOCON SLIM LINE 48
SLIM
48
VIP
Paketversand
Universal
PCM
152 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON SLIM LINE 48
SLIM
48
VIP
Paketversand
Universal
PCM
169 h+
> 120 h
Frozen PCM (-25 bis -15°C)
THERMOCON SLIM LINE 48
SLIM
48
VIP
Paketversand
Universal
PCM
161 h+
> 120 h
Frozen DI (< -15°C)
THERMOCON SLIM LINE 48
SLIM
48
VIP
Paketversand
Universal
Trockeneis
161 h+
> 120 h
Cold (+2 bis +8°C)
THERMOCON SLIM LINE 64
SLIM
64
VIP
Paketversand
Universal
PCM
142 h+
> 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON SLIM LINE 64
SLIM
64
VIP
Paketversand
Universal
PCM
169 h+
> 120 h
Frozen PCM (-25 bis -15°C)
THERMOCON SLIM LINE 64
SLIM
64
VIP
Paketversand
Universal
PCM
127 h+
> 120 h
Frozen DI (< -15°C)
THERMOCON SLIM LINE 64
SLIM
64
VIP
Paketversand
Universal
Trockeneis
110 h+
96 - 120 h
Cold (+2 bis +8°C)
THERMOCON MEDI LINE MEDIUM
MEDI
6
VIP
Paketversand
Universal
PCM
53 h+
48 - 72 h
Ambient / CRT (+15 bis +25°C)
THERMOCON MEDI LINE MEDIUM
MEDI
6
VIP
Paketversand
Universal
PCM
91 h+
72 - 96 h
Frozen PCM (-25 bis -15°C)
THERMOCON MEDI LINE MEDIUM
MEDI
6
VIP
Paketversand
Universal
PCM
35 h+
24 - 48 h
Cold (+2 bis +8°C)
THERMOCON MEDI LINE LARGE
MEDI
18
VIP
Paketversand
Universal
PCM
68 h+
48 - 72 h
Ambient / CRT (+15 bis +25°C)
THERMOCON MEDI LINE LARGE
MEDI
18
VIP
Paketversand
Universal
PCM
91 h+
72 - 96 h
Frozen PCM (-25 bis -15°C)
THERMOCON MEDI LINE LARGE
MEDI
18
VIP
Paketversand
Universal
PCM
50 h+
48 - 72 h
Cold (+2 bis +8°C)
THERMOCON PREMIUM 12
PREMIUM
12
VIP
Paketversand
Universal
PCM
102 h+
96 - 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON PREMIUM 12
PREMIUM
12
VIP
Paketversand
Universal
PCM
72 h+
48 - 72 h
Frozen PCM (-25 bis -15°C)
THERMOCON PREMIUM 12
PREMIUM
12
VIP
Paketversand
Universal
PCM
72 h+
48 - 72 h
Cold (+2 bis +8°C)
THERMOCON PAPER 9
PAPER
9
Papier
Paketversand
Seasonal summer
Wasser
73 h+
72 - 96 h
Cold (+2 bis +8°C)
THERMOCON PAPER 9
PAPER
9
Papier
Paketversand
Seasonal winter
Wasser
99 h+
96 - 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON PAPER 9
PAPER
9
Papier
Paketversand
Seasonal summer
Wasser
74 h+
72 - 96 h
Ambient / CRT (+15 bis +25°C)
THERMOCON PAPER 9
PAPER
9
Papier
Paketversand
Seasonal winter
PCM
99 h+
96 - 120 h
Frozen PCM (-25 bis -15°C)
THERMOCON PAPER 9
PAPER
9
Papier
Paketversand
Universal
PCM
44 h+
24 - 48 h
Frozen DI (< -15°C)
THERMOCON PAPER 9
PAPER
9
Papier
Paketversand
Universal
Trockeneis
108 h+
96 - 120 h
Cold (+2 bis +8°C)
THERMOCON PAPER 13
PAPER
13
Papier
Paketversand
Seasonal summer
Wasser
82 h+
72 - 96 h
Cold (+2 bis +8°C)
THERMOCON PAPER 13
PAPER
13
Papier
Paketversand
Seasonal winter
Wasser
99 h+
96 - 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON PAPER 13
PAPER
13
Papier
Paketversand
Seasonal summer
Wasser
81 h+
72 - 96 h
Ambient / CRT (+15 bis +25°C)
THERMOCON PAPER 13
PAPER
13
Papier
Paketversand
Seasonal winter
PCM
80 h+
72 - 96 h
Frozen PCM (-25 bis -15°C)
THERMOCON PAPER 13
PAPER
13
Papier
Paketversand
Universal
PCM
55 h+
48 - 72 h
Frozen DI (< -15°C)
THERMOCON PAPER 13
PAPER
13
Papier
Paketversand
Universal
Trockeneis
116 h+
96 - 120 h
Cold (+2 bis +8°C)
THERMOCON PAPER 30
PAPER
30
Papier
Palettenversand
Seasonal summer
Wasser
75 h+
72 - 96 h
Cold (+2 bis +8°C)
THERMOCON PAPER 30
PAPER
30
Papier
Palettenversand
Seasonal winter
Wasser
99 h+
96 - 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON PAPER 30
PAPER
30
Papier
Palettenversand
Seasonal summer
Wasser
100 h+
96 - 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON PAPER 30
PAPER
30
Papier
Palettenversand
Seasonal winter
PCM
99 h+
96 - 120 h
Frozen PCM (-25 bis -15°C)
THERMOCON PAPER 30
PAPER
30
Papier
Palettenversand
Universal
PCM
57 h+
48 - 72 h
Frozen DI (< -15°C)
THERMOCON PAPER 30
PAPER
30
Papier
Palettenversand
Universal
Trockeneis
132 h+
> 120 h
Cold (+2 bis +8°C)
THERMOCON PAPER 53
PAPER
53
Papier
Palettenversand
Seasonal summer
Wasser
83 h+
72 - 96 h
Cold (+2 bis +8°C)
THERMOCON PAPER 53
PAPER
53
Papier
Palettenversand
Seasonal winter
Wasser
99 h+
96 - 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON PAPER 53
PAPER
53
Papier
Palettenversand
Seasonal summer
Wasser
79 h+
72 - 96 h
Ambient / CRT (+15 bis +25°C)
THERMOCON PAPER 53
PAPER
53
Papier
Palettenversand
Seasonal winter
PCM
72 h+
72 - 96 h
Frozen PCM (-25 bis -15°C)
THERMOCON PAPER 53
PAPER
53
Papier
Palettenversand
Universal
PCM
54 h+
48 - 72 h
Frozen DI (< -15°C)
THERMOCON PAPER 53
PAPER
53
Papier
Palettenversand
Universal
Trockeneis
136 h+
> 120 h
Cold (+2 bis +8°C)
THERMOCON PAPER 70
PAPER
70
Papier
Palettenversand
Seasonal summer
Wasser
78 h+
72 - 96 h
Cold (+2 bis +8°C)
THERMOCON PAPER 70
PAPER
70
Papier
Palettenversand
Seasonal winter
Wasser
99 h+
96 - 120 h
Ambient / CRT (+15 bis +25°C)
THERMOCON PAPER 70
PAPER
70
Papier
Palettenversand
Seasonal summer
Wasser
76 h+
72 - 96 h
Ambient / CRT (+15 bis +25°C)
THERMOCON PAPER 70
PAPER
70
Papier
Palettenversand
Seasonal winter
PCM
69 h+
48 - 72 h
Frozen PCM (-25 bis -15°C)
THERMOCON PAPER 70
PAPER
70
Papier
Palettenversand
Universal
PCM
46 h+
24 - 48 h
Frozen DI (< -15°C)
THERMOCON PAPER 70
PAPER
70
Papier
Palettenversand
Universal
Trockeneis
120 h+
> 120 h
Keine passenden Artikel für diese Auswahl gefunden. Passen Sie die Filter an.
Sie können mehrere Produkte gemeinsam anfragen.
Understanding pre-qualification
What does “pre-qualified” mean for thermal packaging?
Pre-qualification applies to the tested passive packaging configuration – not to the insulated shipper alone.
The tested system configuration
Insulated shipper
Coolant packs / PCM
Packout
No or minimal payload
Ambient temperature profile
Pre-qualified system
THERMOCON pre-qualifies systems in a worst-case scenario – with no or minimal payload.
Performance data apply to the defined combination of components and test conditions.
Climatic chamber testing under defined conditions
What does the test demonstrate?
The system configuration maintains the specified temperature range for the stated hold time.
Temperature ranges and test profiles
Pre-qualification uses standardised ISTA or AFNOR ambient temperature profiles as well as profiles representative of real-world conditions.
+2 to +8 °C
+15 to +25 °C
−15 to −25 °C
Dry ice
When is reassessment required?
When the product, payload, route, hold time, packing process, coolant conditioning or temperature requirement changes.
Important: no unconditional temperature guarantee
Documented performance applies exclusively to the tested configuration and the underlying test conditions. Suitability must be assessed for the specific application.
From pre-qualification to qualification
From a pre-qualified system to one qualified for your application
Pre-qualification applies to the tested passive packaging configuration – not to the insulated shipper alone.
01
Pre-qualified system
Tested and documented performance data for a defined configuration and defined conditions.
02
Assessment against the shipping process
The proposed packaging is assessed against the customer’s actual or representative conditions.
03
System qualified for the customer’s application
Thermal performance is demonstrated under conditions representative of the customer’s application.
Pre-qualified system
Product specification
Temperature limits
Actual or representative payload
Packout
Conditioning of coolant packs / PCM packs
Shipping route
Seasonal ambient temperature profiles
Transit time
Handling and transfer points
Safety margin
The result determines the next step
Use the existing system
The pre-qualified system meets the requirements in its existing configuration.
Adapt the packout
The positioning, number or conditioning of coolant packs is adjusted.
Develop a bespoke solution
Bespoke thermal packaging is developed for the specific transport process.
Documented evidence of thermal performance can be incorporated into GDP-compliant transport processes.
Choose a packout
Select by coolant pack configuration
If ambient temperatures along the shipping route are predictable, a seasonal packout can be tailored to summer, winter or transitional conditions. This is often more cost-effective, but requires reliable selection of the correct seasonal configuration. Where ambient temperatures vary widely, on international routes or in hot-to-cold or cold-to-hot shipments, a universal packout is usually more suitable, as a single configuration provides more robust protection under changing ambient conditions.
Seasonal Packout
SUMMER / WINTER CONFIGURATION
Adapted to the seasonal temperature profile
Lower material costs
Optimised for clearly defined seasons
More planning and training required
Ideal for stable seasonal processes
Universal Packout
YEAR-ROUND CONFIGURATION
One configuration for changing ambient conditions
Simpler storage and process management
Lower risk of mix-ups
Often higher material costs
Ideal for standardised processes across multiple shipping lanes
Suitable product lines with seasonal packouts
Parcel shipping
Single-use
Classic Line
Cost-effective parcel solution based on EPS shippers
provided that the universal configuration is qualified for the specific shipping route and defined temperature limits.
A seasonal packout is not inherently less safe when correctly selected and appropriately qualified. A universal packout, however, often reduces the risks associated with incorrect seasonal selection and unexpected ambient temperatures.
Frequently asked questions
What is pre-qualified thermal packaging?
Pre-qualified thermal packaging has been tested as a defined system configuration in climatic chambers – with a specified packout, payload, conditioning, hold time and ambient temperature profile. Under these conditions, testing demonstrated that the temperature in the payload compartment remained within the defined target temperature range for the stated hold time.
Is pre-qualified thermal packaging automatically suitable for every shipment?
Pre-qualified thermal packaging is not automatically suitable for every shipment. It demonstrates the thermal performance of a defined system configuration under specified test conditions. Before use, an assessment is needed to establish whether these conditions adequately represent the specific transport process. Customer-specific temperature data, route, payload or hold time may indicate that changes to the packaging system would be beneficial – for example, to the packout, coolant pack configuration or conditioning.
Can pre-qualified thermal packaging be used in GDP-compliant transport processes?
Yes, it can form part of documented GDP-compliant transport processes. Thermal packaging should be regarded as one element of the overall process. It cannot ensure GDP compliance on its own.
What does a hold time of 24h, 48h or 72h mean?
The hold time is the period for which a system remained within the specified temperature range under defined test conditions. Hold times cannot be compared reliably without information on the ambient temperature profile, payload, packout and conditioning.
Which temperature ranges are available?
Typical temperature ranges are +2 to +8 °C, +15 to +25 °C and -15 to -25 °C, alongside dry ice or deep-frozen applications. Bespoke PCM melting points, adapted packouts or customer-specific tests may be appropriate for special requirements.
When is a climatic chamber test necessary?
A climatic chamber test is particularly appropriate when existing test data do not adequately represent the actual transport process, or when product value, product sensitivity, route, temperature requirements, payload, hold time or risk profile call for additional assurance. When qualifying thermal packaging for transport processes subject to GDP requirements, climatic chamber testing is one of the key methods for demonstrating thermal performance under defined or representative conditions. Depending on the application, several rounds of testing and optimisation may be necessary – for example, with different packouts, coolant pack configurations, conditioning procedures, payloads and ambient temperature profiles.
Have a pre-qualified packaging system assessed
Do you already know the required temperature range, hold time, payload or transport type? THERMOCON can help you shortlist a suitable pre-qualified system and assess whether existing data are sufficient for your application or whether an adjustment would be beneficial.
Alle aufgeführten Produkte werden gemeinsam angefragt.
You are currently viewing a placeholder content from Vimeo. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
You are currently viewing a placeholder content from YouTube. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
You are currently viewing a placeholder content from Mailchimp. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
You are currently viewing a placeholder content from Turnstile. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.