THERMOCON Premium Box · Premium 12

Pre-qualified reusable thermal case with VIP and PCM

Premium reusable thermal packaging for transporting temperature-sensitive products. Vacuum insulation panels (VIP) and phase change material (PCM) provide high thermal performance for demanding shipments in pharma, biotech, diagnostics and life sciences.

12 litres

Payload space

Vacuum insulation

High insulation performance, slim walls

Up to 5 days

Temperature control under AFNOR test conditions

PCM

for a year-round packout

TECHNICAL DATA · DIMENSIONS

THERMOCON Premium 12

This compact thermal case offers around 12 litres of payload space. The reusable Premium system is pre-qualified for three temperature ranges.

Payload volume Approx. 12 litres
Payload space dimensions Approx. 228 × 228 × 228 mm
External dimensions including outer carton Approx. 405 × 395 × 445 mm
Shipping durations · Cold, CRT & Frozen

Pre-qualified for three temperature ranges.

The THERMOCON Premium Box was tested in climate chambers with an empty payload space to simulate a thermally demanding worst-case scenario. The tests used summer and winter ambient temperature profiles in accordance with AFNOR NF S99-700.

Ambient / CRT

+15 to +25 °C

3–5 days

Load the PCM packs at room temperature.

WINTER

3–5 days

SUMMER

3–5 days

Cold

+2 to +8 °C

4–5 days

PCM packs keep the temperature stable
at around +5 °C.

WINTER

4–5 days

SUMMER

4–5 days

Frozen

Below −15 °C

3 days

Uses dedicated PCM packs with a phase change temperature of −20 °C.

WINTER

3 days

SUMMER

3 days

Minimum durations are based on the published pre-qualification. Check the payload, transport temperature profile, conditioning, handling and acceptance criteria for your specific application.

Inside the Premium Box

High performance meets elegant design

The THERMOCON Premium Box combines a high level of mechanical and thermal protection with an elegant appearance.

THERMOCON Premium 12 mit Isolierung und gelben PCM-Elementen in Explosionsdarstellung

Exploded view Premium 12 · System components

VIP

Vacuum insulation panels

Slim VIP insulation reduces heat ingress and leaves more room for the payload.

PCM

PCM coolant packs

The PCM configuration helps maintain the required temperature range as ambient temperatures fluctuate.

EPP

Robust EPP insulated box

The lightweight EPP insert provides both thermal and mechanical protection.

CASE

Premium outer case

The carrying handle and latches make the system easy to handle and transport.

DOC

Document compartment

A recess in the lid provides a dedicated space for shipping documents.

LABEL

Label window

Shipping information and labels remain clearly visible from the outside and are easy to replace.

CLIMATE CHAMBER TESTING & PRE-QUALIFICATION

Universal Packout

The THERMOCON Premium thermal case combines VIP insulation with PCM coolant packs. It is pre-qualified for +2 to +8 °C, +15 to +25 °C and below −15 °C under summer and winter temperature profiles.

For each temperature range, the same set of PCM packs and the same pre-conditioning procedure can be used throughout the year. There is no need to change the pack configuration between seasons.

THERMOCON Premium 12: +2 to +8 °C · Duration 102 h
THERMOCON Premium 12, +2 to +8 °C Combined plot of ambient temperature sensor S4 and the three sensors S1 to S3 in the empty payload space. Test period: 2 June 2020 at 17:41:40 to 6 June 2020 at 23:41:40, a duration of 102 hours. The target range of two to eight degrees Celsius is shaded. The curves are approximations traced from the report screenshot; obscured sections were interpolated. The report states that S1, S2 and S3 each spent zero minutes outside the target range. 50 40 30 20 10 0 −10 0 24 48 72 96 °C Time [h] Target range +2 to +8 °C Ambient temperature S4 S1: lower corner of the payload space S2: centre of the payload space S3: upper corner of the payload space Test 591: THERMOCON Premium 12, +2 to +8 °C Combined plot of ambient temperature sensor S4 and the three sensors S1 to S3 in the empty payload space. Test period: 2 June 2020 at 17:41:40 to 6 June 2020 at 23:41:40, a duration of 102 hours. The target range of two to eight degrees Celsius is shaded. The curves are approximations traced from the report screenshot; obscured sections were interpolated. The report states that S1, S2 and S3 each spent zero minutes outside the target range. 50 40 30 20 10 0 −10 0 24 48 72 96 °C Time [h] Target range +2 to +8 °C Ambient temperature S4 S1: lower corner of the payload space S2: centre of the payload space S3: upper corner of the payload space
Ambient temperature S4 Payload space S1–S3 Target range

Worst-case scenario · empty payload space
Pre-qualification under AFNOR NF S99-700

Frequently asked questions

THERMOCON Premium Box: your questions answered

Find answers to common questions about the system components, shipping durations, pre-qualification and reuse.

The Premium Box is a pre-qualified reusable thermal case. The Premium 12 combines a robust outer case with EPP, vacuum insulation panels and PCM coolant packs selected for the required temperature range.

Published configurations cover +15 to +25 °C, +2 to +8 °C and frozen shipments below −15 °C. The stated minimum durations range from three to five days, depending on the temperature range.

No. The durations apply to the specified Premium 12 configuration and the relevant test profile. For your application, factors such as payload, route, handling and acceptance criteria need to be assessed.

Pre-qualification covers the specified combination of case, insulation, PCM coolant packs, conditioning and packout under defined test conditions. It provides a documented basis for assessing the system for your application.

According to the published product information, the Premium 12 is designed for use without partially thawing the coolant packs. Follow the specified conditioning procedure and packing instructions for the selected temperature range.

According to the manufacturer, the components are easy to clean and can be disinfected. For repeated use, we recommend a defined procedure for cleaning, inspection, release for reuse and return logistics.

This mainly depends on the number of use cycles, the return rate, cleaning and inspection costs, replacement parts and the cost of single-use packaging avoided. Assess the costs and savings for your actual shipping network.

THERMOCON

What would you like to find?

Choose the right product category.

Pre-qualified systems

Matched insulation, cooling elements and packout configurations.

Insulated shippers

Insulated packaging without accessories, suited to your shipping format.

Not sure what suits your shipping process?

Get personal advice

THERMOCON

Let’s discuss your shipping needs.

Need product advice or help with a technical question?